  Mega Go Flood Par                              Safety Precautions

ADJ Products, LLC  -  www.adj.com  - Mega Go Flood Par User Manual Page 4

ADJ Products, LLC  -  www.adj.com  - Mega Go Flood Par User Manual Page 3

•  Rechargeable Lithium Battery

•  Mulit-Colors

•   Five Operating Modes

•  Electronic Dimming 0-100%

•   Built in Microphone

•   DMX-512 protocol

•  3-Pin DMX Connection

•   Seven DMX Modes: 1 Channel Mode, 2 Channel Mode, 3 Channel  

    Mode, 4 Channel Mode, 5 Channel Mode, 6 Channel Mode, and 

  7 Channel Mode.

•  ADJ RFC compatiable (Not Included)

•  Power Cord Daisy Chain (See page 14)

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids into or on to your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 23 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

         marked change in performance.

  Mega Go Flood Par 

  

        Warranty Registration

  Mega Go Flood Par                                              Features

The Mega Go Flood Par carries a 3 year limited warranty. Please fill 

out the enclosed warranty card to validate your purchase. All returned 

service items whether under warranty or not, must be freight pre-paid 

and accompany a return authorization (R.A.) number. The R.A. number 

must be clearly written on the outside of the return package. A brief 

description of the problem as well as the R.A. number must also be 

written down on a piece of paper included in the shipping carton. If 

the unit is under warranty, you must provide a copy of your proof of 

purchase invoice. You may obtain a R.A. number by contacting our 

customer support team on our customer support number. All pack-

ages returned to the service department not displaying a R.A. number 

on the outside of the package will be returned to the shipper.

The unit should be mounted using a mounting clamp (not provided), 

affixing it to the mounting bracket that is provided with the unit. 

Always ensure that the unit is firmly fixed to avoid vibration and slip-

ping while operating. Always ensure that the structure to which you 

are attaching the unit is secure and is able to support a weight of 10 

times the unit’s weight. Also, always use a safety cable that can hold 

12 times the weight of the unit when installing the fixture.

The equipment must be installed by a professional, and it must be 

installed in a place where it is out of the reach of people’s grasp.

  Mega Go Flood Par                                          Installation

Summary of Contents for Mega Go Flood Par

Page 1: ...ever you wish without the restrictions of power The built in battery will keep charge for up to 4 5 hours full on from a full single charge This fixture can be used in a stand alone mode or connected...

Page 2: ...ee page 23 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat The fix...

Page 3: ...ttery Should the electrolyte gel come into contact with the skin or eyes flush the area of contact immediately with fresh water and seek medical attention immediately 3 4 Do Not Expose the Battery to...

Page 4: ...le a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller kno...

Page 5: ...nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior...

Page 6: ...speed or F XX color fade speed is displayed 3 If you select color change use the UP and DOWN buttons to adjust the speed between SP 01 slowest and SP 99 fastest Mega Go Flood Par Operating Instructio...

Page 7: ...s the color fade is off and the fixture will now color change at the speed you have set To run the fixture in color fade reverse the instructions Set your color fade speed and set the color change spe...

Page 8: ...utton for 3 seconds to return to default settings and default running mode AUTO RUN This button will run 1 of 16 automatic programs You can scroll through the 16 programs using the and buttons You can...

Page 9: ...hannels 1 2 and 3 will not work when Channel 5 is being used Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 MASTER DIMMER 0 255 0 100 5 0 255 COLOR MACROS See 1 Chan...

Page 10: ...vity control will start working after Channel 5 is past the DMX value of 31 Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 0 255 COLOR MACROS See 1 Channel DMX mode...

Page 11: ...shortens the life of the battery Example If b050 is displayed the battery is at half life If b025 is displayed the battery is at 25 life NOTE When the battery is charging or if the battery life is be...

Page 12: ...plied with products described above Except to the extent prohibited by applicable law all implied warranties made by ADJ Products LLC in connection with this product including warranties of merchantab...

Page 13: ...ADJ Products LLC www adj com Mega Go Flood Par User Manual Page 26 ADJ Products LLC www adj com Mega Go Flood Par User Manual Page 25 Mega Go Flood Par Notes Mega Go Flood Par Notes...

Page 14: ...Mode 3 Channel Mode 4 Channel Mode 5 Channel Mode 6 Channel Mode 7 Channel Mode Warranty 3 Year 1 095 days Limited Warranty See Warranty page for details Please Note Specifications and improvements in...

Reviews: