background image

ADJ Products, LLC  -  www.adj.com  - Mega Go Flood Par User Manual Page 8

ADJ Products, LLC  -  www.adj.com  - Mega Go Flood Par User Manual Page 7

P

ower Supply:

 The ADJ Mega Go Flood Par contains a automatic 

voltage switch, which will auto sense the voltage when it is plugged 

into the power source. With this switch there is no need to worry about 

the correct power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To ensure proper DMX data transmission, when using several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Mega Go Flood Par can be controlled via DMX-512 protocol. The 

Mega Go Flood Par has 7 DMX channel modes, please see page 11 for 

DMX mode. The DMX address is set on the back panel of the Mega Go 

Flood Par. Your unit and your DMX controller require a standard 3-pin 

XLR connector for data input and data output 

(Figure  1).  We  recommend  Accu-Cable  DMX 

cables. If you are making your own cables, be sure 

to use standard 110-120 Ohm shielded cable (This 

cable may be purchased at almost all pro lighting 

stores). Your cables should be made with a male 

and female XLR connector on either end of the 

cable. Also remember that DMX cable must be 

daisy chained and cannot be split.

Notice:

 Be sure to follow figures two and three when making your own 

  Mega Go Flood Par                                                 Set Up

Figure 1

life expectancy of the battery maybe shortened or the device 

in which the battery is used may be damaged by electrolyte 

gel leakage. If the batteries cannot maintain a charge for long 

periods of time, even when they are charged correctly, this may 

indicate it is time to change the battery.

  Mega Go Flood Par                            Battery Precautions

Summary of Contents for Mega Go Flood Par

Page 1: ...ever you wish without the restrictions of power The built in battery will keep charge for up to 4 5 hours full on from a full single charge This fixture can be used in a stand alone mode or connected...

Page 2: ...ee page 23 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat The fix...

Page 3: ...ttery Should the electrolyte gel come into contact with the skin or eyes flush the area of contact immediately with fresh water and seek medical attention immediately 3 4 Do Not Expose the Battery to...

Page 4: ...le a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller kno...

Page 5: ...nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior...

Page 6: ...speed or F XX color fade speed is displayed 3 If you select color change use the UP and DOWN buttons to adjust the speed between SP 01 slowest and SP 99 fastest Mega Go Flood Par Operating Instructio...

Page 7: ...s the color fade is off and the fixture will now color change at the speed you have set To run the fixture in color fade reverse the instructions Set your color fade speed and set the color change spe...

Page 8: ...utton for 3 seconds to return to default settings and default running mode AUTO RUN This button will run 1 of 16 automatic programs You can scroll through the 16 programs using the and buttons You can...

Page 9: ...hannels 1 2 and 3 will not work when Channel 5 is being used Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 MASTER DIMMER 0 255 0 100 5 0 255 COLOR MACROS See 1 Chan...

Page 10: ...vity control will start working after Channel 5 is past the DMX value of 31 Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 0 255 COLOR MACROS See 1 Channel DMX mode...

Page 11: ...shortens the life of the battery Example If b050 is displayed the battery is at half life If b025 is displayed the battery is at 25 life NOTE When the battery is charging or if the battery life is be...

Page 12: ...plied with products described above Except to the extent prohibited by applicable law all implied warranties made by ADJ Products LLC in connection with this product including warranties of merchantab...

Page 13: ...ADJ Products LLC www adj com Mega Go Flood Par User Manual Page 26 ADJ Products LLC www adj com Mega Go Flood Par User Manual Page 25 Mega Go Flood Par Notes Mega Go Flood Par Notes...

Page 14: ...Mode 3 Channel Mode 4 Channel Mode 5 Channel Mode 6 Channel Mode 7 Channel Mode Warranty 3 Year 1 095 days Limited Warranty See Warranty page for details Please Note Specifications and improvements in...