background image

FP CFC

©American DJ Supply

Page 2 of 31

FP CFC

FP CFC Operation Manual

The FP  CFC  controller  can  be  controlled using  a 512-DMX  console.  The Flash  Panel 16  together
with the FP CFC controller can make colorful and dynamic light scenery effects.

Customer Support: 

American DJ

_

 provides  a toll free customer support line, to provide  set up

help  and  to  answer  any  question  should  you  encounter  problems  during  your  set  up  or  initial
operation.  You  may  also  visit  us  on  the  web  at  www.americandj.com  for  any  comments  or
suggestions.  Service  Hours  are Monday  through  Friday  9:00  a.m.  to 4:30  p.m.  Pacific Standard
Time.

Voice:

(800) 322-6337

Fax:  

(323) 582-2941

E-mail:  [email protected]

To purchase parts online visit http://parts.americandj.com

Warning! 

To prevent  or reduce  the risk of electrical  shock or fire, do not expose  this unit to

rain or moisture.

Caution!

 

There are no user serviceable parts inside this unit. Do not attempt any repairs

yourself, doing so will void your manufactures warranty. In the unlikely event your unit may
require service please contact American DJ

_

.

PLEASE recycle the shipping carton when ever possible.

A.

 

Parameter Of FP CFC Control System

Picture 1:The link diagram for the total FP CFC control system

Note:
1)  Every  export  of  the  FP  CFC  controller  can  link  16pcs  slim  wall  lights  at  most.  So  every
controller can control 128pcs at the most. The signal output connector for the last light should be
stopped  by  a Teminator  (1  pc  120_  resistor  inside)  in  order  to  prevent  signal  interruption.  One
controller can control  128pcs but no more then that. When there are more than  128pcs, you will
need to link to a slave controller to control the other lights.
2) Make sure the fixation method  of the lights in the  screen is the  same.  The conjunction  of the
adjacent lights must be close. Make sure there is no aperture between the two adjacent lights.

Summary of Contents for FP CFC

Page 1: ...FP CFC American DJ Supply Page 1 of 31 FP CFC AMERICAN DJ FP CFC...

Page 2: ...in or moisture Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures warranty In the unlikely event your unit may requir...

Page 3: ...s total Every controller can be used as either a master controller or a slave controller The slave controllers are controlled through the master controller The slave controllers are not used for opera...

Page 4: ...F card to make sure that the FP CFC controller can work normally There has been a CF example in your CF card for the screen by fixation method 3 1 The Run Chart The Run Chart must be the BIN file The...

Page 5: ...want have link a 8x8 FP CFC you must order the 8x8 BIN run chart file as the run chart of the FP CFC controller in the content of the Configuration Setting file C FP CFC Controller 1 Parameter Of FP C...

Page 6: ...deo Press the SET UP button until the display shows 2 Press the UP or DOWN buttons to increase decrease the intensity 000 100 of the R G B LEDs At 000 the R G B LED s are off 001 is the lowest intensi...

Page 7: ...h DAT file of the CF card Play the twenty first DAT file of the CF card Play the twenty second DAT file of the CF card Play the twenty third DAT file of the CF card Play the twenty fourth DAT file of...

Page 8: ...nsity Press the SET UP button until the display shows 6 Press the UP or DOWN buttons to increase decrease the intensity 000 100 of the R G B LED s At 000 the R G B LED s are off 001 is the lowest inte...

Page 9: ...s the UP or DOWN buttons to increase decrease the intensity 000 100 of all the RGB LEDs At 000 the R G B LED s are off 001 is the lowest intensity 100 is the highest intensity Press the SET UP button...

Page 10: ...icon to play pause stop the video click the icon to make the video full screen click the icon to capture the picture of the video click the icon to find the parameters of the video 5 Click the icon f...

Page 11: ...anslated by ratio Click it will automatically turn into After input the number in the box When you move the cursor to the box click it It will automatically reveal the height You can also input the nu...

Page 12: ...will be a shortcut on the desktop 2 Double click the shortcut to open the software This is what should be displayed 3 Select Turn Wizard in the Tool menu will be displayed Click and find the AVI file...

Page 13: ...b Naming the DAT file 1 The number from 0 to 9 capital letters as well as small letters and all the symbols of the ASC_ table for example which can be displayed on computer can be used to name the DA...

Page 14: ...on the LCD will be 05 XX123 dat lets say the tenth DAT file of the CF card is ABCDEFG12345678910 dat the display on the LCD will show 10 ABCDEFG123456 c Preview the DAT file 1 Click Play should appea...

Page 15: ...e FP CFCby the 4 fixation methods When the address of the light is 1 the four different pixel distribution diagrams are as follows Fixation method 1 Fixation method 2 Fixation method 3 Fixation method...

Page 16: ...ifferent The pixel distribution are as the diagrams above 3 When the address of the light is 1 the pixel number of the same LED add 16 4 When the address of the light is 1 its pixel distributes from 1...

Page 17: ...FP CFC American DJ Supply Page 17 of 31 FP CFC Link by fixation method 3 Link by fixation method 4 Note...

Page 18: ...When there are no more than 128 lights one controller is enough For example if you want to link a 2x2 FP CFC we show you how to create the run chart and the address link list using four different met...

Page 19: ...zontal coordinate is 2 connects to the second output and its address is 2 The 2 1 means the light whose vertical coordinate is 2 and the horizontal coordinate is 2 connects to the second output of the...

Page 20: ...his means that there are two light modules on the horizontal 2 2 Next click on the icon find the base map file labeled of the fixation method 2 The file located in the Base Map folder of the CF Video...

Page 21: ...zontal coordinate is 2 connects to the second output and its address is 2 The 2 1 means the light whose vertical coordinate is 2 and the horizontal coordinate is 2 connects to the second output of the...

Page 22: ...is means that there are two light modules on the horizontal 3 2 Next click on the icon find the base map file labeled of the fixation method 3 The file located in the Base Map folder of the CF Video s...

Page 23: ...zontal coordinate is 2 connects to the second output and its address is 2 The 2 1 means the light whose vertical coordinate is 2 and the horizontal coordinate is 2 connects to the second output of the...

Page 24: ...is means that there are two light modules on the horizontal 4 2 Next click on the icon find the base map file labeled of the Fixation Method 4 The file located in the Base Map folder of the CF Video s...

Page 25: ...zontal coordinate is 2 connects to the second output and its address is 2 The 2 1 means the light whose vertical coordinate is 2 and the horizontal coordinate is 2 connects to the second output of the...

Page 26: ...ve controller ranges from 17 to 24 in the Device Address List the output number of the No 3 slave controller ranges from 25 to 32 in the Device Address List 3 The output number marked on the master co...

Page 27: ...l the lights must be fixed by fixation method 1 the joining of the adjacent lights must be close make sure there is no opening gap between the two adjacent lights 2 Copy the run chart to the CF card 1...

Page 28: ...n The link method of the second export is also the same 2 2 The link picture of 2x2 FP CFC by fixation method 2 Notice 1 All the lights must be fixed by fixation method 2 the joining of the adjacent l...

Page 29: ...horizontal coordinate is 1 in the screen then the light 1 1 connects to the light 1 2 whose vertical coordinate is 1 and the horizontal coordinate is 2 in the screen The link method of the second expo...

Page 30: ...t the first export of the FP CFC controller connects to the light 1 1 whose vertical coordinate is 1 and the horizontal coordinate is 2 in the screen then the light 1 1 connects to the light 1 2 whose...

Page 31: ...on Setting file of the CF card and copy the name of the run chart between the and the then save it Notice 1 The name must the same as the run chart otherwise the FP CFC controller will not work normal...

Reviews: