66
7-8-2. Hardware descriptions:
RS-485:
Connect to NC-180AZ Receiver or Speed dome camera.
Y:
Transmitter (+)
Z:
Transmitter (-)
A:
Receiver (+)
B:
Receiver (-)
Sensors in:
Each sensor-in port can receive trigger signals from other device to trigger video
recording, alarm and notify function. Please use the dry contact for the sensor in; otherwise it will
cause the damage of sensor input.
Relay out:
Connect one signal line and ground for trigger the device such as Light, Beeper… etc.
1. You must use the dry contact for “Sensor in” otherwise it will cause the module damage.
2. The “Relay out” for NO (Normal Open) type device only.
3. The current must less than 10A, when controlling electric lamp and other device.
4. You must connect USB cable on the USB port of Digi-3200Pro when you want to control the
PTZ camera or Digital I/O ports.
7-8-3. Operate the I/O configurations:
Click
on tool bar to setup I/O configuration and parameters. Users will be able to
Setup
relay, Control relay, Setup sensor, Setup Emergency call
etc. (
Fig.7-8.1
)
Fig. 7-8.1
Fig. 7-8.2