MAINTENANCE
DAILY
- Applicator Cups should be rinsed out with clean warm water to remove any hairs, dirt, etc. immediately
following completion of milking – this should avoid the build up of deposits and prevent chemical solidifying in
the gauze. If foam production becomes slow and/or difficult then the Foaming Applicator cup may be easily
dismantled (see fig. 6 below) for cleaning as follows:-
Unscrew the cup assembly (N) and remove from the end of the lance (P) by gripping the outside of the cup
and turning anti-clockwise.
Carefully lift off and retain the large O-ring (S), then lift out the 3 Filter Gauzes (T) from the cup/retainer (R)
at the end of the lance.
The gauzes may be cleaned by immersion in hot water and any stubborn material removed with a soft brush
before re-assembling in the cup with O-ring on top.
Fig. 6 – DISMANTLING FOAM APPLICATOR FOR CLEANING
Use ONLY a soft dry cloth to clean the electrical enclosure housing when necessary – NEVER use a hose. If the
supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard. Always disconnect the supply cord from the mains power supply BEFORE removing
the enclosure lid.
ANNUAL MAINTENANCE
In order to preserve the efficiency and reliability of the AutoFoamer system, we recommend that the following
parts be replaced EVERY 1 – 2 YEARS, depending on number of cows dipped.
Peristaltic pump tubes
– for
Single Pump
units use kit
AAF/022
.
- for
Twin Pump
units use kit
AAF/023
.
Pressure Switch
– use kit
AAF/013
.