57
Maintenance
20.12 Replacing the Valve
Before you begin:
•
Ensure the fireplace is off and cool before servicing.
•
Disconnect power supply (including battery backup) to the
fireplace and turn off gas supply.
•
Remove the fireplace surround. See
Section 16.0
.
•
Remove barrier screen (recommended). See
Section 14.0
.
•
Remove door assembly (recommended). See
Section 15.0
.
•
Remove burner media (recommended). See
Section 18.0
.
•
Remove panel set (recommended). See
Section 17.0
.
•
Disconnect venting and remove the insert from the masonry
opening
Step 1:
Unplug the wires from the valve.
Figure 20.12.01:
Step 2:
Disconnect gas lines from the valve.
Figure 20.12.02:
Step 3:
Remove the (4) tek screws securing the valve brackets to
the side of the fireplace.
Figure 20.12.03:
Step 4:
Remove the valve brackets and fittings to install on the
new valve.
Figure 20.12.04:
Step 6:
Installation is the reverse of removal. Once installed, light the fireplace and verify proper operation and flame pattern according
to
Section 20.4
and
Section 20.5
of this manual.
Step 5:
Install the fittings prior to the brackets. It may be necessary to move the brass elbows slightly to install the mounting brackets.
Summary of Contents for Inspiration 29