Structure and function
68
Centaya Super BAH0092-6 10.20
The calibration is started
by pressing the button on the control
terminal in the tractor cab or
by pressing the calibration button (Fig. 53/1)
or
Fig. 53
by pressing the button on the TwinTerminal
(Fig. 54).
The calibration button and the button on the
TwinTerminal must be pressed and held during
calibration. The metering roller stops
automatically as soon as the calibration is
finished.
A detailed description can be found in the
"AmaDrill 2" operating manual
"ISOBUS software" operating manual.
Fig. 54
The scope of delivery includes a digital scale
with which the weight of the collected metered
material can be determined.
Fig. 55