Faults
76
ZG-TS BAG0203.2 06.19
9.4
Faults, causes and remedies
Fault
Cause
Remedy
Fertiliser lateral distribution not
uniform.
Fertiliser deposits on the spread-
ing discs and the spreading
vanes.
Clean the spreading discs and
the spreading vanes.
The spreading properties of your
fertiliser differ from those of the
one we tested when creating the
setting chart.
Contact the AMAZONE Fertiliser
Service.
05405-501 111
Too much fertiliser in the tractor
track
Prescribed spreading disc speed
is
not
reached.
Increase tractor engine speed.
Spreading vanes and outlets
defective or worn.
Check the spreading vanes and
outlets. Replaced defective or
worn parts immediately.
The spreading properties of your
fertiliser differ from those of the
one we tested when creating the
setting chart.
Contact the AMAZONE Fertiliser
Service.
05405-501 111
No hydraulic functions
Fluid supply at the tractor is not
switched on.
Switch on fluid supply at the trac-
tor.
Power supply to valve block inter-
rupted.
Check cable, plug and contacts.
Oil filter contaminated.
Replace/clean oil filter. (Seite 89).
Solenoid valve dirty
Rinse solenoid valve
(sivulla 89).
The on-board computer does not
indicate any function
Power supply defective.
Check the power supply
to the on-board computer
The spreading discs do not start
rotating when they are switched
on via the on-board computer
The button for switching on the
spreading disc drive was not held
for at least 3 seconds (safety
function).
Press and hold the button for
switching on the spreading disc
drive for at least 3 seconds.
The oil supply from the tractor is
not switched on
Switch on the oil supply from the
tractor.
The spreading disc speed cannot
be reached.
Oil pressure in the return flow is
too high.
Go to a tractor specialist work-
shop.