Construction and function of the field sprayer
Pantera 4504 CP plus BAG0230.2 07.21
109
6.10
74B
Application rate increase with HighFlow
Optional application rate increase for applying liquid fertiliser.
The maximum application rate is increased to up to max. 400
l/min.
In doing so, the agitator pump is used to increase the application
rate. It is then only partially used as an agitator drive, or not at
all.
When using HighFlow, ensure sufficient agitator capacity.
The high-performance liquid fertilisation is switched on and off
via the control terminal.
The HighFlow valve chest is located under the
covers on the right side of the machine
(1) Additional pressure filter
(2) Switch tap for secondary agitator / draining
the residual quantity from the pressure filter
Agitator running at maximum
0
– Agitator off
Drain pressure filter
Control terminal: Multi-function display
(1) The display of the rate control valve position
as a bar diagram provides information as to
whether the forward speed / application rate
can be increased or the agitator capacity
must be reduced.
The more bars are marked, the greater the
quantity that is delivered to the boom.
(2) The digit (value 1-6) for HighFlow shows the
portion that is used by the agitator pump for
spraying.
(1)
(2)
Summary of Contents for Pantera 4504