Cleaning the implement after operation
Pantera 4504 CP plus BAG0230.2 07.21
197
13.5
216B
Performing chemical cleaning
Chemical cleaning is recommended before critical agent chang-
es and before the implement is decommissioned for a longer pe-
riod of time.
Perform the chemical cleaning after the intensive cleaning.
1. Clean the implement.
2. Fill the spray liquid tank with 100 l of water
and add the cleaning agent according to the
instructions provided by the manufacturer.
To flush in the cleaning agent, the spray
liquid tank must be filled with at least 200 l of
water.
3. Run the pump.
4. TwinTerminal:
Switch on the
circulation cleaning (at least 10 minutes,
observe the instructions from the cleaning
agent manufacturer).
5. Control terminal: Select the agitator and
operate at maximum intensity for one mi-
nute.
6. TwinTerminal:
Stop the circulation
cleaning.
7. Spray out the mixture on the previously
treated field.
List of available cleaning agents
Product
Manufacturer
Agro-Quick
Adama
JET CLEAR
Sudau agro
Proagro Spritzenreiniger
proagro GmbH