Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge
capacitor before servicing, unless testing requires it.
RS5320010 Rev. 1
17
Illustration
Component
Testing
Results
Touch panel
assembly
Continuity is indicated as 100
Ω
and below.
Each pad must be pressed to perform the
following test.
1
2
3
4
5
6
7
8
9
Split
10
Pad
1
2
3
4
5
6
7
8
9
Time Entry
Power
Level
Menu b/d
Start
Stop/Reset
Trace
7 & 4
7 & 6
6 & 5
5 & 4
5 & 3
6 & 3
9 & 6
7 & 3
8 & 7
9 & 4
9 & 7
9 & 8
10 & 4
10 & 9
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Dial panel assembly
Continuity is indicated as 100
Ω
and below.
Each pad must be pressed to perform the
following test.
Dial must be rotated to verify continuity.
A
B
C
1
7
6
5
4
3
8
9
Dial
25%
50%
75%
100%
Start
Pad
25%
50%
75%
100%
Start
Dial
Dial
Trace
1 & 3
1 & 4
1 & 5
1 & 6
1 & 7
1 & 8
1 & 9
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Conditions
Idle Condition:
Oven plugged in, display blank (no other components operating).
Initial Power Up Condition:
Apply power to oven with door closed.
Standby Condition:
Open oven door, light and motors operate.
Cook Condition:
Food load in oven, cook cycle initiated.