RS5320010 Rev. 1
2
WARNING
!
Precautions to be observed before and during
servicing to avoid possible exposure to excessive
microwave energy, or electrical shock disconnect
power to oven.
(A) Do not operate or allow oven to be operated with
door open.
(B) Make the following safety checks on all ovens to
be serviced before activating the magnetron or
other microwave source, and make repairs as
necessary:
•
Interlock operation
•
Proper door closing
•
Seal and sealing surfaces (arcing, wear, and
other damage)
•
Damage to or loosening of hinges and latches
•
Evidence of dropping or abuse
(C) Before turning on microwave power for any
service test or inspection within the microwave
generating compartments, check the magnetron,
waveguide or transmission line, and cavity for
proper alignment, integrity, and connections.
(D) Any defective or misadjusted components in the
interlock, monitor, door seal, and microwave
generation and transmission systems shall be
repaired, replaced or adjusted by procedures
described in this manual before oven is released
to the consumer.
(E) Check microwave leakage to verify compliance
with the federal performance standard should be
performed on each oven prior to release to the
consumer.
WIRING
Good service practice is to never route wiring over termi-
nals and/or sharp edges. This applies to any wiring
without regard to the circuit voltage. Wire insulation ma-
terial and thickness is designed and regulated for electri-
cal spacing purpose only, but cannot always be relied
upon because of possible cuts and/or abrasions, which
can occur during servicing.
External Equipotential Earthing Terminal
Equipment has secondary earthing terminal. Terminal
provides external earthing connection used in addition
to earthing prong on plug. Located on outside of oven
back, terminal is marked with symbol shown below.
Important Information
WARNING
!
To avoid risk of electrical shock, injury, or death, make
sure these earthing instruction are followed.
Earthing Instructions
WARNING
!
To avoid the risk of electrical shock or death, this
equipment must be earthed.
WARNING
!
Do not remove earthing prong when installing
earthed appliance in a home or business that does
not have three wire earthing receptacle, under no
condition is earthing prong to be cut off or removed.
It is the personal responsibility of the consumer to
contact a qualified electrician and have properly
earthed three prong wall receptacle installed in
accordance with appropriate electrical codes.
Should a two prong adapter plug be required temporarily it
is the personal responsibility of the consumer to have it
replaced with properly earthed three prong receptacle or
the two prong adapter properly earthed by a qualified
electrician in accordance with appropriate electrical codes.
Servicing of Earthed Products
The standard accepted color coding for grounding wires
is GREEN or GREEN WITH YELLOW STRIPE. These
earth leads are NOT to be used as current carrying
conductors. It is extremely important that the technician
replace any and all earths prior to completion of the
service call. Under no condition should earth wire be left
off causing a potential hazard to technicians and
consumer.
POWER CORD ELECTRICAL RATING
230 V/20 A
230 V/13 A