CHAPTER 5. OPERATING INSTRUCTIONS
HF28 DC RESISTANCE WELDING SYSTEM
5-20
990-372
10.
Return to the
RUN
screen and
increase the weld time by 1-2
ms. Make several welds and
verify that the upper voltage
limit is reached for every weld,
and the weld pulse stops before
the end of the programmed weld
time.
Weld to a Limit Waveform
11.
Make several more welds and inspect them for consistency of weld quality and/or weld
strength.
NOTE:
When using the Weld to a Limit function, always select a monitor mode that is
different
from the feedback mode. For example:
If you are welding in constant current, put limits on voltage.
If you are welding in constant voltage, put limits on current.
If you are welding in constant power, put limits on current or voltage.