APPENDIX C: CALIBRATION
HF28 DC RESISTANCE WELDING SYSTEM
990-372
C-3
6.
The first calibration screen is the
CAUTION
screen. If you are qualified to
proceed with the calibration press to
continue.
7.
The next page is for the CALIBRATION
SHUNT
. This screen asks for the actual
value of the 1000 micro-ohm shunt.
<CALIBRATION SHUNT>
Shunt value : 0987.6
μΏ
Number change
Proceed
The actual value is printed on the exterior of the R7500-8 shunt. Enter this value using the
number keys, and press to continue.
NOTE:
The next calibration screen is the
CURRENT SHUNT
. It is not necessary to change the
current shunt value unless the internal welding transformer was changed. If it was changed,
remove the top cover and enter the shunt value, which is stamped on the copper conductor
connected to the transformer. Press to continue.
8.
The next two screens are
1. CALIBRATE
D/A HIGH
and
2. CALIBRATE D/A LOW
.
Following the screen instructions, adjust
the energy output using the measuring
parameter feature of the oscilloscope.
NOTE:
Do
not
use a visual
assessment.
Press the period [
.
] key to advance to
the next step.
Calibration Signal
9.
The next calibration screen is
CALIBRATE HIGH
. Disconnect the oscilloscope from the shunt
resistor and connect the output of the shunt resistor to the
VOLTAGE SENSE
INPUT
connector using the male BNC to binding post adapter and voltage sense cable. Follow the
screen instructions for this step and the next step,
4. CALIBRATION LOW
.
Final Calibration Setup
10.
The last calibration screen is
5. END OF CALIBRATION.
Press the
MENU
key. HF28 calibration
is now complete.