Supervisor 3000 Installation Instructions
Page 24
For assistance: [email protected] +1 (909) 591-8431 PUD3628R1-2
Ethernet Communication (Optional)
1. Locate the CPU board on the secured side of the master/
center cabinet.
2. Connect the Ethernet cable to the Ethernet port
[Figure 24].
It is assumed that Ethernet cabling has been run to the
turnstile via conduit and pulled through the conduit opening in
Step 6 of the Anchoring the Turnstile section.
NOTE
Fig. 24
CPU Board
Post-Installation Functions Check
Alvarado turnstiles are thoroughly inspected and tested for proper performance prior to being shipped. Perform the following
function checks to verify the turnstiles have been installed properly and are fully operational. If any problems are encountered
during the functions check, refer to the Troubleshooting section on Page 31.
Before beginning the Post-Installation Functions Check, please read the following brief descriptions of the three SU3000 passage
modes. More information on SU3000 passage modes can be found in the
SU3000 User Guide
.
(Flashing)
Passage Mode
Description
User Status
Display
Open / Closed
Status Light
Controlled Passage
The barrier arms are closed, securing the
lane. Upon receipt of an authorization signal
from an access control system the barrier
arms open, allowing a single passage in the
authorized direction. The barrier arms will
close after the user has passed through the
turnstile or the entry access time (6 second
default) has expired.
This is the default
passage mode the SU3000s are set to
before leaving the factory.
Free Passage
An access control authorization signal is
not required for a user to pass through the
turnstile. Barrier arms are closed until a user
enters the turnstile at which time the barrier
arms automatically open. The barrier arms
will close after the user has passed through
the turnstile or the time delay reset (6 second
default) has expired.
No Passage
No passage is allowed. The barrier arms are
closed and remain closed. Valid electronic
credentials are ignored and passage is not
allowed. The barrier arms will still open if a
fire alarm or life safety input is received.
Passage Modes
Ethernet
Port