Internal Card Reader Installation
Removing Status Light Board
Mounting Screws
Card readers used in connection with the site access control system
are not included with the SU3000. The SU3000 has sufficient room
for the installation of small mullion or slim style proximity card
readers.
Card readers require separate power input – do not pull this power
from the SU3000 power supplies.
1. Locate the card reader mounting bracket [Figure 16].
2. Using a Phillips-head screwdriver, remove the status light board
[Figure 16].
3. Using an open wrench, remove the two (2) hex nuts and remove
the card reader mounting bracket [Figure 17].
4. Install the card reader per manufacturer's instructions.
If the distance between the installed card reader and top channel
lid exceeds the read range of the card reader, shims may be used
to elevate the card reader by a maximum of 3/8" (9.5mm).
DO NOT
allow the card reader to touch the status light board.
5. Using an open wrench, replace and tighten the two (2) hex nuts
that secure the mounting bracket.
6.
Place the status light board over the mounting standoffs
and align the holes. Insert and tighten four (4) Phillips head
mounting screws.
7. Route the output cable through the turnstile and connect to your
access control system [Figure 17].
Fig. 17
Fig. 16
Output cable must be routed down through the access hole.
When removing and reattaching the card reader mounting
bracket and status light board, make sure to re-seat and check
all wire harnesses for damage.