background image

 

 

 

 

 

 
 

 
 
 

TS2200: 

  Tripod Turnstile 

TS2211:

    Tripod Turnstile with Controller and RFID Reader 

TS2222: 

  Tripod Turnstile with Controller and Fingerprint Reader with RFID function 

Please read this document carefully before installation and using the device. 

1. Technical Specifications 

Input Voltage 

AC 220V / 110V,   

50Hz / 60Hz 

Max. Tolerance of Arms 

Center: 80 kg 

End: 40 kg 

Rated Power 

60 W 

Ingress Protection Degree 

IP54 

Operating Environment 

Indoor and Outdoor 

Arm Length (mm) 

500 

Operating Temperature 

-28ºC ~ 60ºC 

Net Weight 

65kg 

Operating Humidity 

5% ~ 85% 

Gross Weight 

75kg 

Flow Rate 

25~48 passages / minute  Dimension(mm)

 

Figure 1  L = 1110, W = 320, H = 980 

Input Control Signal 

Dry contact 

Package Size (mm) 

L = 1200 , W = 440, H = 1080 

1110

98

0

500

320

500

98

0

32

0

1110

740

50

0

740

50

0

 

Figure 1 

2. Arm

 

Installation and Equipment Testing 

2.1 Arm Installation Method

 

Installation procedure 

 

1.

 

Open  the  glue  and  apply  in  the  square  openings  of 
the  arms  as  well  as  the  four  countersunk  screws,  as 
shown  in  figure  2-1.  (This  is  to  prevent  screws  from 
getting loose due to vibration after being used for a 
long time.) 

 

 
 
 
 
 
 
 
 
 

                            Figure 2-1 

TS2200 Series Vertical Tripod Turnstile User Manual 

Version: 1.0 

Time: 2014-3

 

 

This opening shall be 

applied with glue evenly.

Summary of Contents for TS2200 Series

Page 1: ...ght 65kg Operating Humidity 5 85 Gross Weight 75kg Flow Rate 25 48 passages minute Dimension mm Figure 1 L 1110 W 320 H 980 Input Control Signal Dry contact Package Size mm L 1200 W 440 H 1080 1110 98...

Page 2: ...turnstile to finish the self check program 3 Lift the arms manually as shown in figure 2 4 4 Check whether the tripod turnstile and the LED indicators work properly If there is any problem please ref...

Page 3: ...to Ground earth there is wiring interface in the power switch Figure 3 3 3 3 Installation 1 Drilling holes Drill holes based on the locations of the holes shown in figure 3 3 2 Fix the mounting plate...

Page 4: ...ive relay signal and open the turnstile Emergency Switch to keep the turnstile open in case there are fire or other emergencies Direction Indicator Output to connect a LED screen and indicate whether...

Page 5: ...3 Memory Function With the memory function the turnstile could remember at most 20 swipes of one card at one time and allows up to 20 visitors to pass so they don t have to swipe card each time this...

Page 6: ...for more than 6s and then lift the arms manually 5 2 Maintenance Forming maintenance consciousness The tripod turnstile needs to be maintained regularly and repaired once it is damaged It is recommend...

Page 7: ...s not open after authentication It may be caused by lack of permission or a circuit problem 1 Check whether the user has the permission to open the turnstile 2 Use a multimeter to check whether the NO...

Page 8: ...cation TCP IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed Green Arrow 7 Memory Function Disabled Note The Lock Driving Duration is default 5 seconds...

Page 9: ...9 Attachment 2 Connection Diagram Overview...

Page 10: ...10...

Reviews: