1
2
MOUNTING THE END CLAMPS
Begin with the bottom row of the module. Lift the first module onto the truss profiles
and position correctly.
Click in the end clamp by slightly tilting, and slide along to the module frame.
Tighten hex screw to a torque of
15 Nm
.
Please note:
If using end clamps with threaded plates, please
ensure the plate is positioned at 90° to the profile channel.
MOUNTING MODULES
Please note:
The end clamps must be
attached at least 20mm from the end of
each mounting profile.
P
As described, each final module on a module row must be mounted with end clamps.
The same applies to the remaining rows of modules.
Please note:
-
Ensure there is a gap of at
least 20mm
between the clamp and the end of the
truss profile
-
Middle clamps must not be mounted right at the end of the profiles!
-
Modules must only be clamped in the sections prescribed for attachment! These
can be found by consulting the manufacturer’s respective module data sheet.
-
Horizontal and vertical gaps between the modules must be around
20mm
!
P
1
2
3
min. 20 mm
MOUNT THE MIDDLE CLAMP
Click the middle clamp onto the frame of the previous module at a slight angle. Move
the module along until the modules are sitting pressed up to each other!
Tighten hex screw to a torque of
15Nm
.
17
Summary of Contents for AS 2.1
Page 1: ...TILED ROOFS AS 2 1 EN SOLAR INSTALLATION INSTRUCTIONS 1 ...
Page 6: ...MOUNTING WITH ROOF HOOKS VERTICAL MODULE ARRANGEMENT SINGLE DIRECTION 6 ...
Page 14: ...MOUNTING TRUSS PROFILES IN A LATTICE ARRANGEMENT HORIZONTAL MODULE ARRANGEMENT 14 ...
Page 18: ...MOUNTING WITH AL13 X ROOF HOOKS VERTICAL MODULE ARRANGEMENT LATTICE 18 ...