21
8. OPERATION BLOCK DIAGRAM
PRESET
DELAY
EDIT
MODE
UTILTY
PREV/NEXT
Load Preset
10 Factory Preset
128 User Preset
Store Preset
128 User Preset
DIAL
DIAL
Delay
Parameters
DIAL
DIAL
Input Gain
-30dB~+6dB
Step 0.5dB
GEQ01
GEQ30
PREV/NEXT
Gain
Gain
-15dB~+15dB
Step 0.5dB
-15dB~+15dB
Step 0.5dB
DIAL
DIAL
Output Gain
-15dB~+15dB
Step 0.5dB
-30dB~+6dB
Step 0.5dB
PEQ01
PEQ05
Frequency
Bandwidth
Gain
Frequency
Bandwidth
Gain
15.6Hz~16KHz
0.05~3.00OCT
0.05OCT/Step
-15dB~+15dB
Step 0.5dB
0.05~3.00OCT
0.05OCT/Step
-15dB~+15dB
Step 0.5dB
DIAL
DIAL
DIAL
DIAL
DIAL
DIAL
PREV/NEXT
Output Pol.
Normal/Reverse
DIAL
Unit
Delay Unit
Parameter
Temperature
Unit
Parameter
Comm. Setup
Preset Change
RX
Ignore/Accept
ID Select
1~32
PREV/NEXT
Parameter
Parameter
Misc. Setup
Output Meter
Post/Pre Mute
Temperature
LCD Contrast
PREV/NEXT
15.6Hz~16KHz