Axial Cooling Fan not Functioning
Is the oven on and a cook mode started?
No
Starting a cook mode will start the
axial cooling fans. They will remain
on after the oven's initial cook mode
starts.
Yes
Is the axial cooling fan supplied with line voltage?
No
Trace wiring back to the TB 16 and
26 terminal and correct wiring
supply issues.
Axial fans are on terminals:
TB16 E3 and TB 22 A2
TB 16 E4 and TB 22 B2
TB 16 F4 and TB 22 C2
Yes
Replace the axial cooling fan.