T
HEORY
Converge®
▪
Service Manual
▪
M N-47241
▪
Rev 1
▪
6/22
59
STEAM GENERATION
1.The steam mode utilizes an individual heating element to supply the heat needed for steam
generation.
2. On a call for steam the control board sends 12Vdc to the steam element relay. The relay
contacts close and complete the circuit to the steam element.
3.The steam element is energized and after a few seconds the water is supplied.
4.During a steam program the control board will send 12Vdc to the steam valve relay. When
the steam valve relay is energized it completes the circuit to the Y1 steam valve.
5.The Y1 steam valve opens and supplies water to the steam element for the steam generation
in the corresponding chamber.
6.The steam generation cycles at 150-second increments until the end of a cook cycle.
7.The chamber humidity valve will also cycle open and closed in accordance with the recipe
until the end of a cook cycle.
Combi Mode 85 – 525
degrees Fahrenheit
1.Same as steam mode except the temperature range is higher.
Cleaning mode
1.The oven must be at the required temperature before the cleaning cycle starts.
2.Use only Alto-Shaam cleaner CE-47853 when running a cleaning cycle. For a catalyst cleaning
cycle, use only catalyst wash descaler CE-47859. The use of any other cleaning chemical may
damage the catalyst and void the warranty.
3.The oven has five different cleaning modes.
4.The rinse cycle is a mid-day rinse to reduce the grease.
5.The light clean cycle is for light debris.
6.The medium clean is for heavy debris (10 full loads of chicken) in one chamber.
7.The heavy clean is for heavy debris (10 full loads of chicken) in all chambers.
8.The catalyst wash reminder screen displays after 18 hours of cumulative cleaning (example:
after five heavy cleaning cycles).
9.The cleaning pump circulates the cleaning solution from the condensate tank to the cleaning
manifold where it is distributed through hoses and injected into each chamber.
Summary of Contents for Converge CMC-H2H
Page 4: ...FOREWORD Converge Service Manual MN 47241 Rev 1 6 22 4 This page is intentionally left blank ...
Page 55: ...COMPONENTS Converge Service Manual MN 47241 Rev 1 6 22 55 Filter Cooling Air VMC PHD 002015 ...
Page 60: ...THEORY Converge Service Manual MN 47241 Rev 1 6 22 60 This page is intentionally left blank ...
Page 139: ...SCHEMATICS Converge Service Manual MN 47241 Rev 1 6 22 139 ...