O
PERATION
Converge®
▪
Service Manual
▪
M N-47241
▪
Rev 1
▪
6/22
17
How to Calibrate the Temperature Probe
Before you begin
Make sure:
▪
The oven is on, but not in cooking or holding mode.
▪
You have a thermometer.
▪
You have a container filled with ice and water.
Procedure
To calibrate the probe, do the following.
Step
Action
1.
Place the probe and the thermometer in a container of ice water and allow
the temperature to settle to 32°F (0°C).
2.
Touch
the menu icon
a
. The control displays the menu screen.
3.
Touch
the Settings icon
b
. The control displays the General Settings screen.
Continued on next page
CT-TS-013849
a
CT-TS-013852
b