S
CHEMATICS
Converge®
▪
Service Manual
▪
M N-47241
▪
Rev 1
▪
6/22
99
SCHEME
REVISION
/
3
77777
5
11
12
11
10
9
8
7
6
5
4
3
2
1
STEAM
CONTROL
TB-34
TB-32
1017
2017
CB
X4-4
CB
X4-1
08-9
08-12
HAND
SHOWER
RLY
A2
HAND
SHOWER
RLY
A1
06-8
FROM
PS
04-6
NO
COM
A2
A1
NO
COM
A2
A1
TB-22
A2
A1
A2
A1
TB-16
SV
RLY
Y1
1
2
1
2
TB-22
2083
2085
2084
2086
1086
801
1087
804
800
803
802
805
LWS
RLY
1
2
NO
COM
A2
A1
NO
COM
A2
A1
TB-22
TB-22
2110
2097
2111
2098
08-12
08-12
EL
1
EL
2
1
2
1
2
1097
1098
810
811
812
813
LOW
STEAM
STEAM
RELAYS
VALVES
647
648
FROM
CB
X2-9
FROM
CB
X2-10
FROM
CB
X2-7
FROM
CB
X2-8
FROM
CB
X1-5
FROM
CB
X1-3
FROM
CB
X1-6
FROM
CB
X1-4
C1
D1
D4
C4
B1
D2
B2
D1
04-6
A1
A1
A3
A3
06-7
08-10
08-12
08-12
08-12
08-12
08-12
RLY
=
RELAY
LEGEND
EL
=
ELEMENT
Y1
=
STEAM
VALVE
CB
=
CONTROL
BOARD
SV
=
STEAM
VALVE
LWS
=
STEAM
RELIEVE
VALVES
Summary of Contents for Converge CMC-H2H
Page 4: ...FOREWORD Converge Service Manual MN 47241 Rev 1 6 22 4 This page is intentionally left blank ...
Page 55: ...COMPONENTS Converge Service Manual MN 47241 Rev 1 6 22 55 Filter Cooling Air VMC PHD 002015 ...
Page 60: ...THEORY Converge Service Manual MN 47241 Rev 1 6 22 60 This page is intentionally left blank ...
Page 139: ...SCHEMATICS Converge Service Manual MN 47241 Rev 1 6 22 139 ...