M
AINTENANCE
Converge®
▪
Service Manual
▪
M N-47241
▪
Rev 1
▪
6/22
70
Continued from previous page
▪
Inspect
all drain hoses and clamps.
▪
Inspect
all steam water injection lines and clamps for leaks or potential issues.
▪
Inspect
wiring to heating elements. Re-tighten or secure as needed. Record the
amp draw.
▪
Inspect
wiring to the steam element. Re-tighten or secure as needed. Record the
amp draw.
▪
Inspect
the cleaning system pump and hoses for leaks and proper operation.
▪
Check
operation of all electrical cooling fans.
▪
Test
steam injection solenoid.
▪
Test
condensate solenoid.
▪
Check
all electrical connections are properly connected and secure to the
boards.
▪
Check
door hinges and handles. Tighten, secure, or adjust as needed.
▪
Check
door gaskets for damage and seal.
▪
Run
each chamber in convection mode and test operation.
▪
Run
each chamber in steam mode and test operation.
▪
For ovens shipped to New Zealand or Australia,
inspect
the back flow preventer
check valve per AS/NZ3500.1 and AS/NZ3500.2