INSTALLATION
Deluxe Control Cook & Hold
▪
Operator’s Manual
▪
M N-46708
▪
Rev 1
▪
1/20
28
Continued from previous page
Regarding international standard ovens:
If the unit is not equipped with flexible cord and plug, an all-pole country
approved disconnection device which has a contact separation of at least 3mm in
all poles must be incorporated in the fixed wiring for disconnection. When using
a cord without a plug, the green/yellow conductor shall be connected to the
terminal which is marked with the ground symbol. If a plug is used, the socket
outlet must be easily accessible. If the power cord needs replacement, use a
similar one obtained from the distributor.
Hard wired ovens:
Hard wired models must be equipped with a country certified external all pole
disconnection switch with sufficient contact separation. Hard wired models that
are mounted on casters must have a strain relief device (tether) to prevent strain
on the power supply cord. If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN or equivalent must be used.
Restraint
Requirements
Any appliance that is not furnished with a power supply cord but that includes a
set of casters must be installed with a tether. Adequate means must be provided
to limit the movement of this appliance without depending on or transmitting
stress to the electrical conduit. The following requirements apply:
1. Maximum height of casters is 6" (152mm).
2. Two of the casters must be of the locking type.
3. Such mobile appliances or appliances on mobile stands must be installed with
the use of a flexible connector secured to the building structure.
A mounting connector for a restraining device is located on the upper back
flange of the appliance. A flexible connector is not supplied by nor is it available
from the factory.
Continued on next page
NOTICE
Where local codes and CE regulatory requirements apply,
appliances must be connected to an electrical circuit that is
protected by an external GFCI outlet.
WARNING:
Electrical shock hazard
Appliance must be secured to building structure Failure to
observe this precaution may result in damage to the equipment
and severe personal injury.