Page 42
Hydra Series AIP-200 LED Luminaires
Installation & Users Manual
Control 0x10xx
Get Allowed Set Allowed
RDM Parameter IDS
Value
Notes
Implemented
9
9
IDENTIFY_DEVICE
0x1000
9
9
RESET_DEVICE
0x1001
9
9
POWER_STATE
0x1010
9
9
PERFORM_SELFTEST
0x1020
9
SELF_TEST_DESCRIPTION
0x1021
9
CAPTURE_PRESET
0x1030
9
9
PRESET_PLAYBACK
0x1031
9
9
IDENTIFY_MODE
0x1040
9
Manufacturer Specific IDs
Get Al-
lowed
Set Al-
lowed
Param-
eter IDs
Type
Length
Unit
Prefix
Min.
Max.
De-
fault
Description
Description2
9
9
8A00H
U8
1
NONE
NONE
0
100
100
Intensity
0---100%
9
9
8A0BH
U8
1
NONE
NONE
0
64
3
Power UP
Fade Time
0-59 = 0-59 Seconds
60 = 1 Minute
61 = 2 Minute
62 = 3 Minute
63 = 4 Minute
64 = 5 Minute
9
9
8A0CH
U8
1
NONE
NONE
0
2
0
When no DMX
0 = Off
1 = Hold Last Look
2 = Power Up Preset
9
9
8A44H
U8
1
NONE
NONE
0
1
0
Calibration ON/OFF
0 = Factory Calibration Off
1 = Factory Calibration On
9
9
8A92H
U8
1
NONE
NONE
0
255
0
Strobe
0-255
9
9
8A93H
U8
1
NONE
NONE
0
1
0
Zoom Reset
0 - Igonre
1 - Reset
9
9
8A94H
U8
1
NONE
NONE
0
255
0
Duration
0-255
9
9
8A9BH
U8
1
NONE
NONE
0
1
1
Strobe Enable
0 - Disable
1 - Enable
9
9
8AA0H
U8
1
NONE
NONE
0
4
2
LCD Off Time
0 = On
1 = 5 Seconds
2 = 10 Seconds
3 = 30 Seconds
4 = 1 Minute
9
9
8AA6H
U8
1
NONE
NONE
0
1
0
Hour Reset
0 = Ignore
1 = Reset
9
9
8AA2H
U8
1
NONE
NONE
0
64
0
Power Up
0 = Last Set
1 - 20 = Preset 1 - 20
21 - 64 = Color Filter 0 - 43
9
9
8AB0H
U8
1
NONE
NONE
0
43
0
Color Filter
0 -43 = Color Filter 0 - 43
9
9
8AB1H
U8
1
NONE
NONE
1
20
1
PRESET
1 - 20 = Preset 1 - 20
9
9
8AB3H
U8
1
NONE
NONE
1
100
100
POWER LIMIT
Sets and displays power