Page 43
Hydra Series AIP-200 LED Luminaires
Installation & Users Manual
Sensor Information
Sensor # Type Unit
Prefix
Range
Minmum
Range
Maximum
Normal
Minimum
Normal
Maximum
Record value
support
Description
0
00
01
00
-30
125
-20
78
02
LED Temp
1
00
01
00
-30
125
-20
69
02
MCU Temp
2
05
00
00
00
100
00
100
02
RED OUTPUT(%)
3
05
00
00
00
100
00
100
02
GREEN OUTPUT(%)
4
05
00
00
00
100
00
100
02
BLUE OUTPUT(%)
5
05
00
00
00
100
00
100
02
LIME OUTPUT(%)
Status Messages
Sub-Device ID
Status Type
Status Message ID Data Value 1
Data Value 2
DESCRIPTION
0
04
8105H
00
00
ZOOM Sensor is Error
0
04
8106H
00
00
ZOOM Sensor is OK
0
04
8108H
00
00
LED Over-temperature
0
04
8109H
00
00
LED temperature normal
Manufacturer Specific IDs
Get Al-
lowed
Set Al-
lowed
Param-
eter IDs
Type
Length
Unit
Prefix
Min.
Max.
De-
fault
Description
Description2
9
8AB4H
U32
4
NONE
NONE
0
65535
0
Operations Hours
Displays the number of user
hours (time of use) of the
luminaire.
9
8AB5H
U32
4
NONE
NONE
0
65535
0
Fixture Hours
Displays the total number of
hours of the luminaire has
been used.
9
9
8AB6H
U8
1
NONE
NONE
0
1
0
ZOOM Control By
DMX/MANUAL
0 = DMX Control
1 = Manual Control
9
9
8AB7H
U8
1
NONE
NONE
0
255
0
ZOOM level
In Manual mode, this pa-
rameter controls the zoom.
9
9
8AB9H
U8
1
NONE
NONE
0
1
0
ZOOM MODE
0 =WASHS Mode
1 = SPOT Mode