42
Setup
4.6.1
Network Provider Connection
An Optical Patchcord (SM fibre ITU-T G.657B3) with connectors SC/APC, Figure 15: Network provider
connection
b), and Optical connector cleaning material will be required.
Figure 15: Network provider connection
•
Clean the optical connectors of the optical pactchcord, Figure 15: Network provider connection
•
b), of the equipment PON port, Figure 15: Network provider connection
•
a), and the optical wall socket , Figure 15: Network provider connection
•
before connecting using appropriate optical connector cleaning material;
•
Plug one of the patchcord cleaned SC/APC optical connectors on the FiberGateway PON port,
Figure 15: Network provider connection
•
a), observing the alignment mechanism, (a click indicates the connector is secure into place)
•
Plug the other end optical patchcord SC/APC connector on the optical wall socket
•
Accommodate the patchcord excessive length avoiding small bend radius on the patchcord
(30mm minimum bend radius).