9–58
Altera Corporation
Stratix GX Transceiver User Guide
January 2005
Power Down
PMA loop
back
Serial loop
back
Tri-state
toggle
Low
—
—
Reverse
serial loop
back
Transmitter
Receiver
—
—
Notes to
:
(1)
Either leave these pins floating or connect
n_leg
to
GXB_GND
through a 10-k
Ω
resistor and connect
p_leg
to
GXB_VCC
through a 10-k
Ω
resistor to improve the device’s immunity to noise.
(2)
Either leave these pins floating or connect
r)
to
GXB_GND
through a 10-k
Ω
resistor and connect
refclkb(-)
to
GXB_VCC
through a 10-k
Ω
resistor to improve the device’s immunity to noise.
(3)
Altera recommends driving the reference resistor pin low for the powered down transceiver block.
(4)
Transmitter output is tri-stated at the lowest V
OD
setting and is toggling at any other setting. However, the V
O D
is
80% of the selected V
O D
setting.
(5)
Receiver pin is pulled low internally. It must be either left floating or pulled low externally.
(6)
Only the 4-mA setting is supported for reverse serial loopback.
Table 9–2. I/O Pin States During Power-Down (Part 2 of 2)
Operation
Transmitter Pins
Receiver Pins
REFCLKB Pins
Rref Pin
Summary of Contents for Stratix GX
Page 18: ...1 10 Altera Corporation Stratix GX Transceiver User Guide January 2005 Modes of Operation ...
Page 200: ...6 46 Altera Corporation Stratix GX Transceiver User Guide January 2005 Design Example ...
Page 296: ...A 12 Altera Corporation Stratix GX Transceiver User Guide January 2005 8B 10B Code ...
Page 318: ...C 8 Altera Corporation Stratix GX Transceiver User Guide January 2005 Known Issues ...