![Altera Stratix GX User Manual Download Page 21](http://html.mh-extra.com/html/altera/stratix-gx/stratix-gx_user-manual_2910919021.webp)
Altera Corporation
2–3
January 2005
Stratix GX Transceiver User Guide
Stratix GX Analog Description
Programmable Voltage Output Differential (V
OD
)
Stratix GX transceivers let you customize the differential output voltage
(V
OD
) to handle different length, backplane, and receiver requirements
). You can select the V
OD
(differential) from a range of 400
to 1,600 mV, as shown in
.
Figure 2–3. V
OD
(Differential) Signal Level
shows the differential output voltage (V
OD
) setting per current
level for each of the on-chip transmitter programmable termination
values.
Single-Ended Waveform
Differential Waveform
(VOD (Differential) = 2 x VOD (single-ended))
Positive Channel (p) = V
OH
Negative Channel (n) = V
OL
Ground
V
OD
V
OD
V
OD
p
−
n = 0 V
V
CM
Table 2–1. Programmable V
O D
(Differential)
100
Ω
(mV)
120
Ω
(mV)
150
Ω
(mV)
400
480
600
800
960
1,200
1,000
1,200
1,500
1,200
1,440
1,400
1,600
Summary of Contents for Stratix GX