Altec AIR, LLC
P210WLP Series Air Dryer User’s Guide
Page 83 of 91
P017455 – Rev. C
13.15
Compressor Won’t Build Pressure
Possible Cause
Check
Corrective Action
Low System Pressure
Verify System Pressure
(section 8.9 )
Adjust System Pressure
to 50 PSI, ± 2 PSI.
(section 8.9 )
Leak in air system
Check all hoses and
fittings between
compressor and Air
Tank for air leaks
(section 9.13 )
Connect, tighten, or
replace leaking
component
Compressor Piston
Leaking
Check the pressure of
the outlet air coming
from the compressor to
the pressure setting on
the capacity control
valve
Replace the compressor
piston seal included in
the Annual
maintenance kit
13.16 Compressor Excessive AMP Draw
Possible Cause
Check
Corrective Action
Restriction in air line
Remove Discharge
Hose from compressor
(hose to the heatless
Dryer)
Re-measure
Compressor AMP
Draw
(section 9.2 )
If measurement is
below the
recommended amps,
trace hoses from
compressor to Capacity
Control Valve looking
for restrictions or kinks
Compressor failing
Remove Discharge
Hose from compressor
(hose to the heatless
Dryer)
Re-measure
Compressor AMP
Draw
(section 9.2 )
If measurement is still
above the
recommended amps,
replace the compressor
(section 11.1)
or send it in for repair
(section 12. )