Altec AIR, LLC
P210WLP Series Air Dryer User’s Guide
Page 41 of 91
P017455 – Rev. C
8.7.12.8
Press the Left (
) Arrow Button to escape to the system setup menu
screen
8.8 Open Panel
8.8.1
Open panel latches and remove
the top panel.
8.9 Setting the System Pressure
With Compressor running:
8.9.1
Open Panel (see section 8.8 ).
8.9.2
Pull the Capacity Control Valve knob out.
8.9.3
Turn the knob until the reading on the
Pressure Gauge is
50 PSI
.
8.9.4
Push the knob in to lock.
8.9.5
Close Panel.
8.10 Setting the Outlet Pressure
8.10.1
Locate the outlet pressure regulator on the front of the unit