Altec AIR, LLC
P210WLP Series Air Dryer User’s Guide
Page 57 of 91
P017455 – Rev. C
9.4.3
Use a Voltmeter to
measure across the board
terminals where wires #4
and #5 are connected.
The voltage should measure
110
- 125 VAC
for the P210WLP or
208 - 253 VAC
for the P212WLP.
9.4.4
Close Panel.
If the incoming voltage measures less than indicated above, it is recommended
that steps be taken at your facility to increase the power to the recommended level
of voltage.
9.5 Testing Consistent Heatless Dryer Cycling
With the Compressor
running
:
9.5.1
Locate the purge port on
the rear of the unit
WARNING!
Internal surfaces may be hot
. Use care when coming into contact
with internal components as there is a potential for some of these
components to become hot when in operation or standby.