20
We reserve the right to modify technical specifications without prior notice.
83050700aUK – Translation of the operating manual
© Alpha-InnoTec GmbH
Example:
control panel in upper recesses
push down the hooked in control panel, until it
latches into place…
push the control cable of the heating and heat
pump controller into the
right‑hand
socket on the
underside of the control panel…
note.
A connection to a computer or a network can
be made via the left socket at the bottom of the
control panel, thereby allowing the heating and
heat pump controller to be controlled remotely
from there. This requires a shielded network
cable (category 6) to be laid through the unit
during the electrical connection work.
Installing the control panel
Danger!
risk of fatal electric shock!
all electrical connection work must be
carried out by qualified electricians only.
Before opening the unit, safely disconnect
the system from the power supply and
prevent it from being switched back on!
There are 4 each recesses at different heights in the
front panel of the unit for fastening the control panel:
1 four upper recesses
2 four lower recesses
There are 4 hooks at the rear of the control panel,
which are used to hook the control panel on the front
panel of the unit:
Hook the control panel's hooks into the recesses
of the front panel (either in the upper or lower
recesses)...