rinsing, filling and bleeding
the system
Rinse, fill and bleed the heating circuit...
In addition, bleed the condensor of the heat pump...
•
open the lower facing panel...
•
open the bleeding valve...
following bleeding, close the lower facing panel.
Insulating the hydraulic
connections
Insulate the vibration decouplers and the pipes of the
heating circuit.
notICe.
Insulate in accordance with applicable lo-
cal standards and directives.
notICe.
the electric heating element is connected
for 6kW at the factory in units with inte-
grated electic heating elements. It can be
connected for 2 (3) or 4 kW (6kW) on the
contactor.
for further information, see the adhesive label
on the electric heating element.
notICe.
the control element of the heat and heat
pump regulator can be connection with a
computer or network using an network
cable designed for such pruposes, thus al-
lowing the heating and heat pump regula-
tor to be controlled remotely.
If such a connection is desired, install a
screened network cable (category 6, with
rJ-45 plug) through the unit when install-
ing the connections and run it through the
front facade of the unit, parallel to the al-
ready-present heating and heat pump reg-
ulator control cable.
close electrical switch cabinet of unit....
Attach the lower facing panels.