Air ducts (with air duct accessories) must be ordered
separately.
ADDITIONAL ACCESSORIES
The installation accessories (vibration decouplers)
for air/water indoor installation heat pumps must be
ordered separately.
Installation and assembly
Observe the following when performing all work:
NOTICE.
Always comply with applicable accident pre-
vention regulations, statutory regulations, ordi-
nances and directives.
WARNING!
The heat pump or heat pump system may
be installed and assembled only by a quali-
fied technician!
NOTICE.
Observe the sound levels of the respective
model.
Overview “Technical data / scope of delivery”,
“Sound” section.
INSTALLATION LOCATION
ATTENTION
Install the unit only indoors.
The installation area must be frost-free and dry. It must
meet the requirements of DIN EN 378. It must also fulfill
applicable local regulations.
Dimensional drawing and installation plan for
respective model.
TRANSPORT TO INSTALLATION LOCATION
To prevent damage during transport, always transport
the unit to final installation location in its original packag-
ing, using a lifting truck.
If it is not possible to transport the unit to the final instal-
lation location using a lifting truck, you can also transport
the heat pump using a hand truck or with pipes.
DANGER!
Several people are required to transport
the unit. Do not underestimate the weight
of the unit.
Overview “Technical data / scope of delivery”,
“General unit data” section.
DANGER!
Unit is not fastened to the wooden pallet.
Danger of tipping over during transport!
This can result in personal injury and dam-
age to the unit.
– Take suitable precautionary measures
to eliminate the danger of tipping.
DANGER!
Make sure to secure unit against slipping
during transport.
ATTENTION
Never use components and hydraulic connec-
tions on the unit for purposes of transport.
ATTENTION
Do not damage the hydraulic connections under
any circumstances.
ATTENTION
Do not tilt the unit more than a maximum of 45°
(in any direction).
LIFTING THE UNIT WITH PIPES
The units can be lifted with
3
/
4
" and/or 1" pipes (provided
by customer) that are suitable for the weight of the
respective unit. Special holes are provided in the frame
for this purpose.
Proceed as follows:
Remove lower facing panels on the switch cabinet
side (= operator side) of the unit. To do so, loosen
quick-release screws. Turn counter-clockwise 90°…