ADM-SDEV-BASE/XCKU060 User Manual
V1.0 - 27th November 2018
3.5.1 Automatic Temperature Monitoring
At power-up, the control logic sets the temperature limits and resets the temperature sensor's over-temperature
interrupt.
The temperature limits are shown below :
.
FPGA
Board
Min
Max
Min
Max
Industrial
-40 degC
+100 degC
-40 degC
+100 degC
Table 10 : Temperature Limits
Important:
If any temperature limit is exceeded, the FPGA is automatically cleared. This is indicated by the Green LED
(FPGA Configured) switching off and the two status LEDs showing a temperature fault indication.
The purpose of this mechanism is to protect the card from damage due to over-temperature.
3.5.2 Microcontroller Status LEDs
LEDs D2 (Red) and D1 (Green) indicate the microcontroller status.
LEDs
Status
Green
Running and no alarms
Green + Red
Standby (Powered off)
Flashing Green + Flashing Red
(together)
Attention - critical alarm active
Flashing Green + Flashing Red
(alternating)
Service Mode
Flashing Green + Red
Attention - alarm active
Red
Missing application firmware or
invalid firmware
Flashing Red
FPGA configuration cleared to
protect board
Table 11 : Status LED Definitions
Page 14
Functional Description
ad-ug-1360_v1_0.pdf