2.1 COMPOSITION OF THE PRODUCT AND DIAGRAM OF CONNECTION
2
CONTROL UNIT 870N
2.2 FUNZIONI DIP SWITCH 870N
DIP 1
DIP 2
DIP 3
FUNCTION
OFF
OFF
OFF
SETTING
AWNING
: INPUT ANEMOMETER and INPUT STEP BY STEP. Working time
60
se-
conds.
REGULATION WIND THERSHOLD BY TX
ON
OFF
OFF
SETTING
VASISTAS
: INPUT RAIN SENSOR and INPUT OPEN/CLOSE and CLOSE/STOP. Wor-
king time
40
seconds.
OFF
ON
OFF
SETTING
SHUTTER
: INPUT. OPEN/STOP and CLOSE/STOP. Working time
40
seconds.
OFF
OFF
ON
SETTING
AWNING
: INPUT ANEMOMETER and INPUT STEP BY STEP. Working time
120
seconds.
REGULATION WIND THERSHOLD BY TX
ON
OFF
ON
SETTING
VASISTAS
: INPUT RAIN SENSOR and INPUT OPEN/CLOSE and CLOSE/STOP. Wor-
king time
120
seconds.
OFF
ON
ON
SETTING
SHUTTER
: INPUT. OPEN/STOP and CLOSE/STOP. Working time
120
seconds.
ON
ON
OFF
LIGHTS SETTING: INPUT ON/OFF LIGHT 1 and ON/OFF LIGHT 2.
ON
ON
ON
LIGHTS SETTING: INPUT ON/OFF LIGHT 1 and ON/OFF LIGHT 2.
WARNING: USE THE LIGHT SETTING IF THE LIGHTS ARE PRESENTS, RISK OF DAMAGING THE CONTROL UNIT IF THE MOTOR
GETS CONNECTED
Setting:
VASISTAS
Setting:
LIGHTS