4.3  REGULATION OF THE WIND BY TX (IF SET BY DIP SWITCH) 

 

4.2  DELETING A TX BY TRANSMITTER 

 

 

 

 

 

 

 

1) Press and hold the 
PROGRAMMING 
switch of a TX already 
stored. 

2) After some se-
conds the motor will 
do TWO short oppo-
site movements. 

3) Release the PRO-
GRAMMING switch of 
the TX already stored. 

4) Press IMMEDIATLY 
the STOP switch of the 
TX to store. 

 5) The motor will do 
TWO short opposite 
movements. 

6) 

RESET accompli-

shed.

 

 

 

 

 

 

 

1) Press and hold 
the PROGRAM-
MING switch of a 
TX already stored. 

2) After some se-
conds the motor will 
do TWO short oppo-
site movements. 

 

3) After some seconds 
the motor will do TWO 
further short opposite 
movements. 

4) Release the PRO-
GRAMMING switch of 
the TX altready stored. 

 5) If the CLIMB switch 
is pressed, 15 km/h 
will be set. 

Choose 

just one switch. 

6)  If the  STOP 
switch is pressed, 
25 km/h will be set. 
Choose just one 
switch . 

 

7) If you pree the 
DESCENT switch, 35 
km/h will be set. 

Choose just one 
switch. 

 

8) Once you pressed the 
wanted switch, the mo-
tor will do TWO short 
opposite movements of 
confirmation. 

 

9) 

REGULATION OF 

THE WIND SPEED 
ACCOMPLISHED. 

4.4 INVERSION OF THE MOTOR MOVEMENT BY TX

 

 

 

 

 

 

 

1) Press and hold the 
PROGRAMMING 
switch of the TX al-
ready stored. 

2) After a few seconds 
the motor will do TWO 
short opposite move-
ments. 1 BEEP 

3) After a few seconds 
the motor will do 
TWO further short 
opposite movements. 
2 BEEP 

4) After a few seconds 
the motor will do TWO 
further short opposite 
movements. 3 BEEP 

 5) Release the PRO-
GRAMMING switch of 
the TX altready stored. 

6) 

INVERSION OF 

THE MOTION AC-
COMPLISHED.

 

Summary of Contents for 870N

Page 1: ...E Ferrari 28 30037 Scorz VE Italy Tel 39 041 5841973 Fax 39 041 5841979 www almot it info almot it 870N CONTROL UNIT FOR MOTORS 230 VAC AWNINGS SHUTTERS VASISTAS LIGHTS INSTRUCTION MANUAL AND USE ENG...

Page 2: ...of the device has to be made according to the instructions of the manufacturer Non compliance with these rules can compromise the safety The implementation of the electrical installation of voltage s...

Page 3: ...G TIME 40 60 120 SEC WIND THERSHOLD 12 25 35 Km h MAX TX MEMORIZABLES 15 RX RADIO FREQUENCY 433 92 Mhz PROTECTION DEGREE IP 55 SIZE 115 x 35 x 23 mm 1 2 1 COMPOSITION OF THE PRODUCT AND DIAGRAM OF CON...

Page 4: ...seconds OFF ON OFF SETTING SHUTTER INPUT OPEN STOP and CLOSE STOP Working time 40 seconds OFF OFF ON SETTING AWNING INPUT ANEMOMETER and INPUT STEP BY STEP Working time 120 seconds REGULATION WIND THE...

Page 5: ...ing the installation with the continuous opening and closing of the awning shutter or vasistas the motor gets stuck this is not because of a damage of the board but because of the thermic protector co...

Page 6: ...er short opposite movements 4 Release the PRO GRAMMING switch of the TX altready stored 5 If the CLIMB switch is pressed 15 km h will be set Choose just one switch 6 If the STOP switch is pressed 25 k...

Page 7: ...h for 3 seconds and release 2 The control unit will make a long sound 4 Press IMMEDIATLY the STOP switch of the TX to delete 5 The motor will do TWO short opposite move ments 6 RESET accomplished BEEE...

Page 8: ...EN 6100 4 4 ENV 50140 EN 50081 1 EN 50082 1 Declares at the same time that it is forbidden to put into service the abovementioned products before that the machine to which they are incorporated or ar...