background image

S.G. Elettronica S.r.l  

-  Via E. Ferrari , 28  -  30037 Scorzè (VE) Italy  -  Tel +39 041 5841973  Fax +39 041 5841979  -  www.almot.it  -  [email protected]

 

DIP 4 

FUNCTION 

OFF 

Settings of the working times 

STANDARD

ON 

Settings of the 

TEST 

timings of work (the wor-

king times are reduced to 

10—12 

seconds). 

2.3 FUNCTIONS DIP SWITCH  870N

 

3.0 GENERAL RULES OF FUNCTIONING 

 

 

During the wiring 

strictly respect the diagram of connection

, a wrong connection 

could damage the 

installation

. Follow the diagram more appropriate to the installation. (

paragraph 2.1

 

Do not use

, for the command, 

stable position switches

 

Do not exceed 50 mt 

of cable between the control unit and the anemometer. 

 

After supplying the control unit (in case of installation on an awning) position 

the awning on half of 

the run

, rotate the sensor and check that 

after the alarm happened 

(flashing red led), the awning goes up 

(closing). In case that it goes backwards, invert the wires on the MOTOR OPENS clamp, to the MOTOR 
CLOSES clamp. 

 

Position the sensor in an optimal position for receiving the wind, as close to the awning as possible. 

 

If during the installation, with the 

continuous opening and closing 

of the awning, shutter or vasistas, 

the motor gets stuck

, this is 

not because of a damage 

of the board, but because of the 

thermic protector 

contained in the motor. 

Wait until the motor has cooled down and try again

4. 0  PROGRAMMING FIRST TX MASTER BY REMOTE (IF THERE IS NO TX STORED)

 

4.1  PROGRAMMING OF OTHER TX BY MASTER TRANSMITTER

 

DIP 5 

FUNCTION 

OFF 

Functioning of the command switches 

IMPUL-

SIVE. 

ON 

Functioning  command  switches

 

t

o  DEAD 

MAN.  

 

 

 

 

 

1) Supply the control unit  2) The motor will do 

two short opposite 
movements which indi-
cate that 

there are no

  

TX stored in the control 
unit’s memory 

3) 

Within a few seconds 

press the 

STOP

 switch of 

the TX to memorize.  

 4) The motor will do two 
short movements which 
indicate that the TX has 
been memorized. 

Release 

the STOP  of the 
TX. 

5) Programming accompli-
shed. 

 

 

 

 

 

 

1) When the control unit 
has been supplied, press 
and hold the hidden 
switch of the 

TX master 

already

 stored. 

2) The motor will do 
two short movements 
which indicate 

the 

storing has begun.

 

4) 

Within a few se-

conds 

press the 

STOP

 

switch of the TX to 
memorize.  

 5) The motor will do 
two short move-
ments which indicate 
that the TX has been 
memorized.  

6) Programming 
accomplished. 

3) Release the hidden 
switch of the TX. 

Summary of Contents for 870N

Page 1: ...E Ferrari 28 30037 Scorz VE Italy Tel 39 041 5841973 Fax 39 041 5841979 www almot it info almot it 870N CONTROL UNIT FOR MOTORS 230 VAC AWNINGS SHUTTERS VASISTAS LIGHTS INSTRUCTION MANUAL AND USE ENG...

Page 2: ...of the device has to be made according to the instructions of the manufacturer Non compliance with these rules can compromise the safety The implementation of the electrical installation of voltage s...

Page 3: ...G TIME 40 60 120 SEC WIND THERSHOLD 12 25 35 Km h MAX TX MEMORIZABLES 15 RX RADIO FREQUENCY 433 92 Mhz PROTECTION DEGREE IP 55 SIZE 115 x 35 x 23 mm 1 2 1 COMPOSITION OF THE PRODUCT AND DIAGRAM OF CON...

Page 4: ...seconds OFF ON OFF SETTING SHUTTER INPUT OPEN STOP and CLOSE STOP Working time 40 seconds OFF OFF ON SETTING AWNING INPUT ANEMOMETER and INPUT STEP BY STEP Working time 120 seconds REGULATION WIND THE...

Page 5: ...ing the installation with the continuous opening and closing of the awning shutter or vasistas the motor gets stuck this is not because of a damage of the board but because of the thermic protector co...

Page 6: ...er short opposite movements 4 Release the PRO GRAMMING switch of the TX altready stored 5 If the CLIMB switch is pressed 15 km h will be set Choose just one switch 6 If the STOP switch is pressed 25 k...

Page 7: ...h for 3 seconds and release 2 The control unit will make a long sound 4 Press IMMEDIATLY the STOP switch of the TX to delete 5 The motor will do TWO short opposite move ments 6 RESET accomplished BEEE...

Page 8: ...EN 6100 4 4 ENV 50140 EN 50081 1 EN 50082 1 Declares at the same time that it is forbidden to put into service the abovementioned products before that the machine to which they are incorporated or ar...