Allied Construction Products, LLC www.alliedcp.com
TM103349_SP1000B_15sep
19
11.0 Troubleshooting Guide
This guide identifies commonly encountered
conditions along with the recommended corrective
action. For conditions other than these, contact Allied
Technical Service.
CAUTION
Only qualified personnel, having knowledge of the
machine’s systems, proper test equipment and
tools shall attempt adjustments and repairs.
Fault
Possible Cause
Corrective Action
No operation
Insufficient oil pressure or flow
Check hydraulic supply. Correct as
necessary
Failed bearings
Inspect. Replace bearings as necessary
Failed motor
Inspect. Replace as necessary
Erratic operation
Erratic oil pressure or flow
Check hydraulic supply. Correct as
necessary
Failed spring mount
Inspect. Replace mount as necessary.
Operation with excessive
noise or vibration
Failed bearing
Inspect. Replace as necessary
Imperfect bearing lubrication
Check oil level, quality & type (1000)
Loose bolts or mounting
hardware
Inspect. Tighten bolts as necessary
Operation stalls under load
Pressure relief too low
Check hydraulic supply. Correct as
necessary
Failed bearing.
Inspect. Replace bearing as necessary
Motor internal bypass failed
seals or worn gears
Inspect. Replace motor as necessary
Operation smooth, but at
reduced speed
Insufficient oil flow
Check hydraulic supply. Correct as
necessary
If motor or flow regulator valve was
replaced, check both for proper match
Oil discharge from relief vent
(Model 1000)
Oil level too high
Check oil level. Do not overfill
This Allied work tool is not self-powered and its
performance level will be impaired by a hydraulic
system that is not operating properly or set outside
the accepted specifications.
If the carrier machine is equipped with an adjustable
work mode switch, verify its proper setting for Skid-
Pac operation.
Use a flow meter to measure oil delivery and to verify
the cracking pressure of the relief valve. When
troubleshooting, include all parts associated with the
auxiliary circuit, including the hoses to exclude
possibility of a collapsed hose.
Tools required for testing include a flow meter and
pressure gages. Test procedures, along with a form
to record the results of the flow test, can be found in
the Technical Data section of this manual.