Sequence of Operation - LINE-IN HI-SPEED,
Option Code D
If the operator selects
HI-SPEED
mode by the rocker
switch on the control panel, an electric solenoid valve on
the control manifold sends pilot pressure to the X1 port on
the motor. Pressure commands the servo to reduce motor
displacement to increase line speed. If working pressure
increases to PCOR setting, the motor servo begins to
increase displacement to increase line pull.