Section 4
4 - 35
1.
Install the counterbalance relief (CBR) manifold on
the mounting bracket. Leave mounting bolts loose.
2.
Install the control manifold. Torque capscrews to 28
ft-lbs (38 N-m).
3.
Reinstall hose and tube assemblies. Alternately
tighten connections to prevent placing motor tubes
in a bind. Adjust mounting bracket as necessary to
align with manifold.
4.
Reinstall covers as shown. Torque M12 hardware
to 66 ft-lbs (90 N-m). Torque M16 hardware to 165
ft-lbs (225 N-m).