Allied Construction Products, LLC www.alliedcp.com
18
TM102783_BreakerLube CML_15jul
6.0 Installation – [cont’d]
6.10.1 Basic Wiring ‘1E’ Motor (LLC Disabled)
For Basic On / Off Operation of Motor Without LLC,
refer to Fig. 6-18 1E. Wire the fuse and momentary
switch per diagram.
Fig. 6-18 ‘1E’ Power to Motor – Basic Circuit
RD/1 Red (+)
BK/3 Black (Not used)
BN/2 Brown ( - )
YE/GN (Ground)
1. Route and connect the power wire (RED) to the
(+) side of battery after the in-line fuse and foot
switch.
2. Route and connect the brown wire to negative
side of battery (-).
Fig. 6-19 Plug (41) 2-Pole Plus Ground
6.11 Gray Connector (26) Identified
The gray connector is keyed to fit the plug (28)
located on the right side of the pump housing. It is
pre-wired with a 4-conductor cable and used to wire
the low level control to an alarm.
Fig 6-20 Gray Connector
Fig. 6-21 Low Level Control Wired to Dash Lamp
One option is to use the low level control switch with
a warning light. Or, add a relay and the switch can be
used to activate a warning light and disable the
breaker’s operating valve.
RD/1 Red (+)
BK/3 Black (+)
BN/2 Brown (Not Used)
YE/GN (Not Used)
M
1
2
3
1
2
3
1E
41- Plug 2-Poles Plus Ground
1
2
3
1
2
3
20
28
26
1
2
3
(+) RD/1
BK/3