112
Goldeye
G
Technical
Manual
V
2.0.0
Temperature
control
SensorTemperatureSetpointActivate
Type:
Command
Activates
the
currently
selected
SensorTemperatureSetpointSelector
.
Access:
Unit:
Visibility: Beginner
Values:
SensorTemperatureSetpointValue
Type:
Float
FPA
temperature
value,
depends
on
SensorTemperatureSetpointSelector
.
Access:
R
Unit:
ºC
Visibility: Beginner
Values:
Measured
/Calculated
value
DeviceTemperatureSelector
Type:
Enum
Selects
the
location
of
temperature
measurement
points
within
the
camera.
Access:
R/W
Unit:
Visibility: Beginner
Values:
Sensor,
Sensorboard,
Mainboard
DeviceTemperature
Type:
Float
Device
temperature,
measured
at
the
location
selected
by
DeviceTemperatureSelector
.
Access:
R
Unit:
ºC
Visibility: Beginner
Values:
DeviceRelativeHumiditySelector
Type:
Enum
Selector
used
for
determination
of
the
relative
humidity.
Access:
R/W
Unit:
Visibility: Beginner
Values:
Sensorboard
DeviceRelativeHumidity
DeviceControl
Category
for
temperature
management
Table
51:
GenICam features for temperature management (continued)