32
Goldeye
G
Technical
Manual
V
2.0.0
Technical
data
Camera
dimensions
Mounting
the
camera
You
can
attach
the
camera
to
a
base
in
two
ways:
1. To
attach
the
camera
to
any
horizontal
or
vertical
base,
four
mounting
threads
M4
x
6mm
are
located
on
each
side
of
the
camera,
except
for
the
back
side.
‐
Refer
to
the
drawings
below
for
the
exact
distances
between
the
mounting
threads.
‐
To
avoid
damaging
the
camera
housing,
we
recommend
to
use
bolts
with
an
effective
length
of
4
to
6
mm
and
apply
a
maximum
torque
of
2.0
Nm
to
each
bolt.
2. To
attach
the
camera
to
the
common
mounting
plate
of
tripods
used
in
pho
‐
tography,
a
1/4
‐
20
UNC
mounting
thread
is
located
on
the
camera
bottom.
Caution:
Ensure
the
camera
does
not
disengage
from
base.
The
camera
can
disengage
from
its
base
and
fall
down
if
not
properly
attached.
Attach
the
camera
either
with
four
metal
bolts
with
an
effective
length
of
not
less
than
4
mm
and
apply
a
torque
of
2.0
Nm
to
each
bolt,
or
use
the
UNC
thread
and
a
mechanical
safe
guard.