Specifications
89
Alvium CSI-2 Cameras User Guide V2.8.1
Relative QE
1800 C-130 VSWIR
Storage temperature
-20 °C to +85 °C ambient temperature
Operating temperature
Hardware
option
Housing
Cooling areas
1
Mainboard
2
Bare board
3
Not applicable
-20 °C to +85 °C -20 °C to +85 °C
Open housing
4
-20 °C to +65 °C
Relative humidity
0% to 80% (non-condensing)
Digital interface
MIPI CSI-2 D-PHY V1.1; 1, 2, or 4 lanes; maximum 1.051 Gbps per lane
Camera controls
V4L2 controls (Video4Linux Access), Direct Register Access
1
See
2
Output by
DeviceTemperature
3
Ensure that the sensor is operated in the temperature range specified by the manufacturer. For any
www.alliedvision.com/en/support
4
Temperature values must be observed for the housing
and
for the cooling areas.
Figure 18: Alvium 1800 C-130 VSWIR (Sony IMX990) relative QE
Feature
Specification
Table 33: Alvium 1800 C-130 VSWIR specifications (sheet 2 of 2)
0%
10%
20%
30%
40%
50%
60%
70%
80%
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
Quantum E
ĸ
ciency
[%]
Wavelength [nm]
Sony IMX990, IMX991
ƌĞůĂƟǀĞ
QE