Camera interfaces
218
Alvium CSI-2 Cameras User Guide V2.8.1
Output levels
Status LED
Alvium CSI-2 cameras have a green status LED. The following table describes the
flashing pattern indicating different events. Inverse flashing: If the LED is already
on, it is switched off for a short time.
Normal operation
NOTICE
Damage to the camera by high output current or voltage
The camera can be damaged when connected to a device that exceeds the specified
maximum current or voltage. Consider maximum values:
• Max. current = 12 mA per output
• Max. Out VCC = 3.3 VDC
Parameter
Value
External output voltage U
out
(low)
0 to 0.4 VDC
External output voltage U
out
(high)
2.4 to 3.3 VDC
Undefined levels
0.4 to 2.4 VDC
Maximum external output voltage
3.3 VDC
Maximum output current
12 mA
Table 111: GPIOs as output, current and voltage levels
Output voltage for U
Out
(high) = On state
The voltage level in the On state depends on the load current. Higher currents yield
lower voltage.
LED codes
Behavior
Status
Continuously active
Power on or idle state
Irregular flashing
Command or image traffic,
such as for camera startup
Four short flashes and
code sequence
Error state
Table 112: LED codes for normal operation