Specifications
57
Alvium CSI-2 Cameras User Guide V2.8.1
Sensor shutter types
Differences between global shutter (GS), rolling shutter (RS), and global reset
shutter (GRS,
GenICam for CSI-2 Access
only) sensors are explained in
on page 239. Triggering behavior differs between
cameras with global shutter (GS) and rolling shutter (RS). See
220 for details.
Operation for medium power consumption
Values for power consumption in the specification tables are based on following
parameters:
• Factory settings (camera after startup)
• Minimum exposure time
• Maximum frame rate
• Full resolution
• Pixel format (monochrome and color models)
-
GenICam for CSI-2 Access
: Mono8 or Bayer8
-
Other access modes:
RAW8 (GREY)
• Camera operation in freerun mode
• Without bandwidth limitations.
Dimensions and mass
For your model’s dimensions, see
In manufacturing, camera board and sensor are moved against each other to
adjust flange focal distance. The value range for camera length with open housing
cameras reflects in the technical drawings. See
Digital binning
Selected Alvium 1800 C cameras combine digital horizontal binning and digital
vertical binning, for integer values 1 to 8.
Alvium 1800 C models
≥
12 MP resolution
If digital horizontal and digital vertical binning are set to 1× and the digital vertical
binning value is increased, digital horizontal binning is automatically set to 2×.
GenICam
for CSI-2
Access