Specifications
55
Alvium CSI-2 Cameras User Guide V2.8.1
Operation for maximum frame rates
Values for maximum frame rates and for minimum and maximum exposure time in
the specification tables are based on following parameters:
• Factory settings (camera after startup)
• Minimum exposure time
• Full resolution
• Pixel format
-
GenICam for CSI-2 Access
: Mono8 or Bayer8 pixel format
-
Other access modes:
RAW8 (GREY) for monochrome and color models
• Camera operation in freerun mode
• Without bandwidth limitations.
Continued from the previous page.
ExposureMode = TriggerWidth or TriggerControlled
In addition, most global shutter (GS) cameras can control exposure time by the
trigger signal, with the
ExposureMode
set to
TriggerWidth
or
TriggerControlled
(using
ExposureStart
and
ExposureStop
).
The trigger controlled exposure time is extended automatically:
• If the trigger controlled exposure time does not match the available
increment, the camera automatically extends the exposure time to the next
increment.
• Subsequently, the
exposure time offset is added
.
You can use
ExposureActive
to determine the duration of the exposure time
offset.
GenICam
for CSI-2
Access